External Wall Fire Review · EWS1 v3, March 2022

What is an EWS1 form?

An EWS1 form is the External Wall Fire Review: a short standard form on which a suitably qualified professional records the outcome of an assessment of a building's external wall construction and attachments. Lenders use it when deciding whether to lend on a flat. It is not a safety certificate and not a survey.

DOCUMENT ILLUSTRATIONOption recorded · professional sign-off
The form
EWS1 — External Wall Fire Review. Current version v3, March 2022. The wording is fixed; amending it invalidates the form.
Signed by
A suitably qualified and competent professional with appropriate professional indemnity cover for external-wall work, who takes responsibility for the assessment.
Who it is for
Valuers and mortgage lenders. Completed once per building, not per flat, and generally treated as valid for five years unless the building changes.
What it is not
Not a fire risk assessment, not a safety certificate, not a warranty. The technical work behind it is a Fire Risk Appraisal of External Walls (FRAEW), commonly to PAS 9980:2022.
Worked example

What a completed EWS1 looks like

Scroll through a complete document. The notes alongside explain each part as you go. The content is fictional and the photos are placeholder slots.

Loading example…

Styled to your firm

Your logo and accreditation marks, your brand colours, and your choice of cover, header, footer and photo layout. Set it once in Settings and every report follows.

Or your own report, built for you

Keep the format your firm already uses: we recreate it as a private template, or build a report type we don’t list. You approve a real PDF before you sign up. Bespoke report templates →

Download the EWS1 example (PDF) The complete PDF, exactly as SurveyorSuite exports it — no sign-up needed to download.

What goes on an EWS1 form

The form itself is deliberately short — identify the building, state the assessment route and its outcome, sign it. The record around it is what the assessor has to keep.

  1. ADocument detailsClient organisation (usually the building owner or managing agent), building address and postcode, document reference, date of form, and the professional confirmation that reasonable skill and care were used to investigate the primary external wall materials and attachments.
  2. BAssessmentThe route — Option A or Option B — and then the outcome within it: A1, A2 or A3 under Option A, B1 or B2 under Option B. Selecting an option is also a confirmation that you meet the membership and competence criteria in the form's guidance notes.
  3. CSignatory detailsName, qualifications, organisation, professional body and membership number, signature and date — plus the AI-use disclosure block the named signatory confirms before export.
  4. DRevision historyOptional. Forms get re-issued as buildings change, so each earlier issue is recorded with its date, reference and rating — the document carries its own audit trail.

The rating options

  • A1 Option A, where the primary wall materials are of limited combustibility or better and cavity barriers are installed to an appropriate standard: no attachments whose construction includes significant quantities of combustible materials.
  • A2 Option A: an appropriate risk assessment of the attachments confirms that no remedial works are required.
  • A3 Option A: neither of the above applies, so there may be costs of remedial works to the attachments.
  • B1 Option B, where combustible materials are present in the wall itself: the fire risk is sufficiently low that no remedial works are required.
  • B2 Option B: the fire risk is sufficiently high that remedial works are required.

The point most often got wrong: A1, A2 and A3 grade the attachments, not the wall — Option A already presumes the wall itself is of limited combustibility or better. There is no B3.

When an EWS1 is asked for

The trigger is almost always a lender or a valuer. A flat is being sold or remortgaged, the valuer flags the external walls, and the lender wants the position communicated in a format it recognises. The form was introduced in December 2019 by RICS with UK Finance and the Building Societies Association to give that conversation a consistent shape. Its scope has narrowed considerably since — see our guide on whether one is needed at all.

The usual trigger

A lender or valuer asks for one

Whether one is required is driven by the individual lender's current policy and the specific building — not by a blanket height rule. Government advice since 2021 has been that EWS1 forms should not be requested for blocks of flats below 18m, and many lenders have reduced or dropped the requirement. Check the lender's criteria before instructing.

Who signs

Competence scales with the route

Option A can be completed by a qualified member of a relevant construction-industry body able to identify the wall materials and check cavity barriers. Option B needs a chartered or incorporated fire engineer or equivalent competence. Whoever signs must hold PI cover that extends to external-wall work — a known sticking point.

One per building

Not per flat, and it expires

A single form covers the whole building and is generally treated as valid for five years, unless something about the building changes. Re-issues are common, which is why the revision history matters — a reader needs to see what was previously rated and when.

EWS1 vs FRAEW vs fire risk assessment

Three different documents that get used interchangeably in conversation. Only one of them is the technical appraisal.

Comparison EWS1 form FRAEW (PAS 9980:2022) Fire risk assessment
What it is A one-page standard form recording a conclusion The technical appraisal of the external wall construction that produces that conclusion A separate assessment of fire safety in a building, carried out under fire-safety law
Audience Valuers and mortgage lenders The building owner, and the assessor's own file The responsible person and the enforcing authority
Length Short — identification, route, outcome, signature Long — wall build-up by element, attachments, risk factors, recommendations Varies with the building
Wording Fixed. Amending it invalidates the form Written by the assessor, to the PAS 9980 methodology Written by the assessor
Relationship Summarises the FRAEW conclusion for a lender Underpins the EWS1 rating Independent of both — an EWS1 does not satisfy it
In SurveyorSuite Built in — sections A–D Not offered Not offered

How SurveyorSuite produces an EWS1

SurveyorSuite is report-writing software for UK surveyors. The EWS1 structure above is built in, with the form's own wording and the option routing already wired.

Optional AI drafting

AI drafts the narrative. The classification stays yours.

Dictate notes on site or type them up afterwards. The AI turns them into the descriptive content around the form — what was inspected, what was found, what any additional notes need to say — and fills your signatory details from your firm settings.

What it does not do: propose an A1–B2 outcome. That is a regulated professional judgement with direct PI consequence, so the field is closed to AI output; the named signatory selects it and signs. The AI works only from what you wrote — it does not invent fire test data, insulation types or cavity details. AI use is disclosed in Section C and timestamped in the audit trail. The feature is optional; the software works the same way without it.

Read our full AI compliance position
In the editor
  • EWS1 sections A–D built in
  • Option A / Option B routing to the right sub-questions
  • Form wording reproduced, not paraphrased
  • Revision history for re-issued forms
  • Export blocked until required fields are done
Photos
  • Bulk import from the camera roll
  • Drag each photo to its section
  • Arrow, box and label annotations
  • Numbered appendix with two-way Fig. links
  • Works offline on iOS and Android, syncs later
Output
  • Branded PDF with your logo and colours
  • Word (.docx) export for further editing
  • Clickable contents page
  • Client database and audit trail
  • Cloud archive for long-term retention

SurveyorSuite is £35 a month on your own, or £35 per paid seat with colleagues (£30 per paid seat on annual billing, ex-VAT), with all 16 report types and unlimited reports included.

EWS1 FAQs

Is an EWS1 form still needed?
Sometimes, but far less often than in 2020. EWS1 was introduced in December 2019 as a way to unblock flat lending, and its scope has narrowed since. Following expert advice in 2021 that there is no systemic fire risk in blocks of flats below 18m, government said EWS1 forms should not be requested for those buildings, and many lenders reduced or dropped the requirement. Whether one is needed today turns on the individual lender's policy and the specific building — height, cladding type and quantity — not a blanket rule. Always check current lender criteria before instructing.
What is the difference between A1, A2, A3 and B1, B2?
A1, A2 and A3 sit under Option A, which applies where the primary external wall materials are of limited combustibility or better and cavity barriers are installed to an appropriate standard. They grade the attachments, such as balconies. A1: no attachments whose construction includes significant quantities of combustible materials. A2: an appropriate risk assessment of the attachments confirms no remedial works are required. A3: neither applies, so there may be costs of remedial works to attachments. B1 and B2 sit under Option B, where combustible materials are present in the wall itself: B1 — the fire risk is sufficiently low that no works are required; B2 — the fire risk is sufficiently high that remedial works are required. There is no B3.
Who can complete and sign an EWS1 form?
A suitably qualified and competent professional with the expertise to assess the external wall construction, carrying professional indemnity cover that extends to that work. Competence scales with the route: Option A can be completed by a qualified member of a relevant construction-industry body able to identify the wall materials and check cavity barriers; Option B needs a chartered or incorporated fire engineer or equivalent competence. The signatory takes responsibility for the assessment, which is why competence and the scope of PI cover matter as much as the conclusion.
Is there a free EWS1 form template?
The EWS1 form is a published standard form, and the current version is v3 (March 2022). Its wording is fixed — amending it, other than as the form's own notes permit, renders it invalid, so there is no scope for a "better" third-party version. Work from the current published form rather than a copy that may be out of date. The value is not in the document: it is in the assessment behind it and the competence of whoever signs. The worked example above shows a completed form in context. In SurveyorSuite the form wording, the Option A / Option B routing and the revision history are built into the software.
How long is an EWS1 valid for?
It is generally treated as valid for five years from the date of the form, and it covers the whole building rather than an individual flat. That validity assumes nothing material about the building changes — remedial works, alterations or new information about the wall construction can all mean a fresh assessment is needed sooner. Re-issued forms should record the earlier issues, which is what the revision history section is for.
Is an EWS1 the same as a FRAEW or a fire risk assessment?
No, and the distinction matters. A FRAEW — Fire Risk Appraisal of External Walls, most commonly carried out to PAS 9980:2022 — is the technical appraisal of the wall build-up and attachments that produces the conclusion. The EWS1 is the short form that communicates that conclusion to a lender. A fire risk assessment is a separate exercise under fire-safety law, covering the building as a whole; an EWS1 does not satisfy it and does not replace it. An EWS1 is also not a safety certificate, a guarantee or a warranty.
Will the AI choose the A1–B2 outcome?
No. The option and outcome are a regulated professional judgement carrying direct PI consequence, so the field is closed to AI output as a deliberate safeguard. Optional AI drafting assists with the descriptive content around the form — what was inspected, what was found, any additional notes. The named signatory selects the route and the outcome, and signs.
Is SurveyorSuite's AI aligned with the RICS AI standard?
SurveyorSuite is designed to support firms working under the RICS Professional Standard Responsible use of artificial intelligence in surveying practice (in force from 9 March 2026). Actual generative-AI use is disclosed in Section C, generation events are timestamped in the internal audit trail and the delivered report prints the named signatory's reliability attestation. That attestation is supporting evidence, not the full written reliability decision required by s.4.2. The named professional remains accountable. RICS does not certify software and SurveyorSuite does not guarantee compliance. See our full AI compliance position.
What happens to my notes? Are they used to train AI models?
No. Inspection notes are sent only to a commercial AI provider listed in our AI Supplier Reference Card. The card identifies the current providers, their contractual no-training position and retention terms, with links to primary sources. Before using the feature, anonymise private or confidential data where practical, and do not upload it without express written consent in advance and your firm's assessment that the upload creates no unacceptable risk.