An EWS1 form is the External Wall Fire Review: a short standard form on which a suitably qualified professional records the outcome of an assessment of a building's external wall construction and attachments. Lenders use it when deciding whether to lend on a flat. It is not a safety certificate and not a survey.
- The form
- EWS1 — External Wall Fire Review. Current version v3, March 2022. The wording is fixed; amending it invalidates the form.
- Signed by
- A suitably qualified and competent professional with appropriate professional indemnity cover for external-wall work, who takes responsibility for the assessment.
- Who it is for
- Valuers and mortgage lenders. Completed once per building, not per flat, and generally treated as valid for five years unless the building changes.
- What it is not
- Not a fire risk assessment, not a safety certificate, not a warranty. The technical work behind it is a Fire Risk Appraisal of External Walls (FRAEW), commonly to PAS 9980:2022.
What a completed EWS1 looks like
Scroll through a complete document. The notes alongside explain each part as you go. The content is fictional and the photos are placeholder slots.
Loading example…
Styled to your firm
Your logo and accreditation marks, your brand colours, and your choice of cover, header, footer and photo layout. Set it once in Settings and every report follows.
Or your own report, built for you
Keep the format your firm already uses: we recreate it as a private template, or build a report type we don’t list. You approve a real PDF before you sign up. Bespoke report templates →
What goes on an EWS1 form
The form itself is deliberately short — identify the building, state the assessment route and its outcome, sign it. The record around it is what the assessor has to keep.
- ADocument detailsClient organisation (usually the building owner or managing agent), building address and postcode, document reference, date of form, and the professional confirmation that reasonable skill and care were used to investigate the primary external wall materials and attachments.
- BAssessmentThe route — Option A or Option B — and then the outcome within it: A1, A2 or A3 under Option A, B1 or B2 under Option B. Selecting an option is also a confirmation that you meet the membership and competence criteria in the form's guidance notes.
- CSignatory detailsName, qualifications, organisation, professional body and membership number, signature and date — plus the AI-use disclosure block the named signatory confirms before export.
- DRevision historyOptional. Forms get re-issued as buildings change, so each earlier issue is recorded with its date, reference and rating — the document carries its own audit trail.
When an EWS1 is asked for
The trigger is almost always a lender or a valuer. A flat is being sold or remortgaged, the valuer flags the external walls, and the lender wants the position communicated in a format it recognises. The form was introduced in December 2019 by RICS with UK Finance and the Building Societies Association to give that conversation a consistent shape. Its scope has narrowed considerably since — see our guide on whether one is needed at all.
A lender or valuer asks for one
Whether one is required is driven by the individual lender's current policy and the specific building — not by a blanket height rule. Government advice since 2021 has been that EWS1 forms should not be requested for blocks of flats below 18m, and many lenders have reduced or dropped the requirement. Check the lender's criteria before instructing.
Competence scales with the route
Option A can be completed by a qualified member of a relevant construction-industry body able to identify the wall materials and check cavity barriers. Option B needs a chartered or incorporated fire engineer or equivalent competence. Whoever signs must hold PI cover that extends to external-wall work — a known sticking point.
Not per flat, and it expires
A single form covers the whole building and is generally treated as valid for five years, unless something about the building changes. Re-issues are common, which is why the revision history matters — a reader needs to see what was previously rated and when.
EWS1 vs FRAEW vs fire risk assessment
Three different documents that get used interchangeably in conversation. Only one of them is the technical appraisal.
| Comparison | EWS1 form | FRAEW (PAS 9980:2022) | Fire risk assessment |
|---|---|---|---|
| What it is | A one-page standard form recording a conclusion | The technical appraisal of the external wall construction that produces that conclusion | A separate assessment of fire safety in a building, carried out under fire-safety law |
| Audience | Valuers and mortgage lenders | The building owner, and the assessor's own file | The responsible person and the enforcing authority |
| Length | Short — identification, route, outcome, signature | Long — wall build-up by element, attachments, risk factors, recommendations | Varies with the building |
| Wording | Fixed. Amending it invalidates the form | Written by the assessor, to the PAS 9980 methodology | Written by the assessor |
| Relationship | Summarises the FRAEW conclusion for a lender | Underpins the EWS1 rating | Independent of both — an EWS1 does not satisfy it |
| In SurveyorSuite | Built in — sections A–D | Not offered | Not offered |
Background reading: What is an EWS1 form? · See also HHSRS assessments and Schedules of Condition.
How SurveyorSuite produces an EWS1
SurveyorSuite is report-writing software for UK surveyors. The EWS1 structure above is built in, with the form's own wording and the option routing already wired.
AI drafts the narrative. The classification stays yours.
Dictate notes on site or type them up afterwards. The AI turns them into the descriptive content around the form — what was inspected, what was found, what any additional notes need to say — and fills your signatory details from your firm settings.
What it does not do: propose an A1–B2 outcome. That is a regulated professional judgement with direct PI consequence, so the field is closed to AI output; the named signatory selects it and signs. The AI works only from what you wrote — it does not invent fire test data, insulation types or cavity details. AI use is disclosed in Section C and timestamped in the audit trail. The feature is optional; the software works the same way without it.
Read our full AI compliance position- EWS1 sections A–D built in
- Option A / Option B routing to the right sub-questions
- Form wording reproduced, not paraphrased
- Revision history for re-issued forms
- Export blocked until required fields are done
- Bulk import from the camera roll
- Drag each photo to its section
- Arrow, box and label annotations
- Numbered appendix with two-way Fig. links
- Works offline on iOS and Android, syncs later
- Branded PDF with your logo and colours
- Word (.docx) export for further editing
- Clickable contents page
- Client database and audit trail
- Cloud archive for long-term retention
SurveyorSuite is £35 a month on your own, or £35 per paid seat with colleagues (£30 per paid seat on annual billing, ex-VAT), with all 16 report types and unlimited reports included.
EWS1 FAQs
Is an EWS1 form still needed?
What is the difference between A1, A2, A3 and B1, B2?
Who can complete and sign an EWS1 form?
Is there a free EWS1 form template?
How long is an EWS1 valid for?
Is an EWS1 the same as a FRAEW or a fire risk assessment?
Will the AI choose the A1–B2 outcome?
Is SurveyorSuite's AI aligned with the RICS AI standard?
What happens to my notes? Are they used to train AI models?
Produce EWS1 forms in SurveyorSuite
£35 a month solo, £35 per paid seat for a team. All 16 report types, unlimited reports.
1-month free trial · card captured, nothing charged during the trial · cancel any time
Last reviewed: · General information for professionals, not fire-safety or legal advice. Always work to the current published EWS1 form, current guidance and your own assessed competence. SurveyorSuite is not a fire-engineering practice and is not affiliated with or endorsed by RICS.